Berchtold s30 service manual


















Request Parts. Add to My Bench. This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details.

I Agree. Site Links. Subscribe To eNews. Im looking for that part Reply. Can someone email me a clean copy. Steam sterilization at C; 2. The sleeves must lie free and must not come into contact with any other items being sterilized. However, if it is necessary, the handles should be sterilized loose at C; 3 minutes.

Damaged grip sleeves must not continue to be used. Note: Sterilizable handles are subject to natural wear. As a rule, a life of approx. Ceiling cover Flange tube dia. Lamp housing hood Lamp frame Light emission lens Sterilizable hand grip sleeves Rail encircling hand grip Control unit. Lamp frame Light emission lens Sterilizable hand grip sleeves Rail encircling hand grip Control unit. Switch on the light Switch off the light Increase intensity Decrease intensity LED indicates that the control unit has a fault Switch from surgical area light to surround light option only Switch from surround light to surgical area light Enlarge field size only with LFN option Reduce field size only with LFN option.

Repeated short presses increase the illuminance in steps. Repeated short presses decrease the illuminance in steps. By pressing Key 6 EndoLite the surgical area illumination is switched off and the surround lighting is switched on 7 Only with the EndoLite option. By pressing Key 7 OP light the EndoLite surround lighting is switched off and the surgical area lighting is switched on again.

By pressing and holding down Key 8 field size large the light field is continuously enlarged up to the maximum value. Repeated short presses enlarge the light field in steps.

By pressing and holding down Key 9 field size small the light field is continuously reduced down to the minimum value. Repeated short presses reduce the light field in steps. Booster activation 1. Press key 4 Bright until LED flashes up in the key max.

The light booster will be activated by pressing simultaneously the key 1 ON and 3 Bright. Luminous power rises from kLux to kLux. The light booster is deactivated by switching off the light with key 2 OFF.

Switch on the light Switch off the light Increase intensity Decrease intensity LED indicates that the control unit has a fault Switch from surgical area light to surround light option only Switch from surround light to surgical area light. By pressing Key 6 EndoLite the surgical area illumination is switched off and the surround lighting is switched on.

By turning the hand grip in the clockwise direction the light field is enlarged, by turning anti-clockwise the light field is reduced. The surgeon must perform the optimum field setting himself in accordance with the size of the operation opening. There is an optimum contrast when the field size is set approx. Thus the adaptation of the surgeons eyes in the whole field of vision is improved. By pressing and holding down Key 8 see control unit page 14 the light field is continuously enlarged up to the maximum value.

By repeated short presses the light field is enlarged in steps. By pressing and holding down Key 9 see control unit page 14 the light field is continuously reduced down to the minimum value. By repeated short presses the light field is reduced in steps. The new sterilized replacement sleeve is pushed onto the sleeve mounting until it touches the stop and is then turned in a clockwise direction until the sleeve locks into place.

It can then be removed from the sleeve mounting. The new sterilized replacement sleeve is pushed onto the sleeve mounting until it touches the stop and is then turned in a clockwise direction until the sleeve is heard locking into place. The light field plotter is an electronic control system, which moves the lamps by electric motor.

An infrared beam which is reflected by a reflector disk controls the light field plotter. The operator can direct the light field to the position which guarantees optimum illumination of the surgical area, by means of a reflector disk, the so-called Light Pilot.

The Light Pilot should be held in the centre of the light field as far as possible and then slowly moved to the desired position. If movement is too quick, the light field will not be able to follow the Light Pilot. This rule is: Wherever the light field is , the Light Pilot will be hit by the infrared beam and can reflect the beam back. For directions about cleaning, disinfection and sterilization, see page CZ Order no.

CZ Only possible if the light has been prepared for an additional arm in advance Supply carrier arm for up to 25 kg load with AC and PA connections, prepared for gas supply. This option must be ordered with the lighting system not upgradeable.

Wall control unit for installation into a wall indicator panel. EndoLite - an environment illumination f0r MIS-surgeries, a 20 Watts halogen bulb integrated in the light head, activated when the main light is switched off. In the event of failure of the main lamp, switch over to a reserve lamp occurs automatically and the reserve lamp swivels automatically into the former position of the main lamp.

A red indicator lights up on the lamp housing when the lamp safety system has switched over to the reserve lamp. The defective main lamp should then be exchanged as quickly as possible. The bulbs must be replaced in the following manner: The symbol with the meaning Danger - Risk of Burning is placed on the lamp support.

Switch off the lighting system and let it cool down risk of burning. During replacement of the lamps the patient must not be touched as it is possible to come into contact with parts under tension. Release and remove sterilizable handle. Unscrew the knurled screw on the underside of the light by turning anti-clockwise. Pull out the whole light system at the hand grip.

Remove a faulty halogen lamp. Fit a new halogen bulb into the bulb holder, - for the booking reference number see paragraph 3. During a lamp change check the bulb holder for scorch marks.

If scorch marks are present, inform our service department. Fit the light system back into the holder picture 4 an screw up the knurled crews in a clockwise direction. Switch the lighting system on and check that the lamp is on and the red indicator light is off.

If other bulbs are used, all guarantees regarding performance and operation will lapse. Remaining illuminance inside at the bottom of a standardised tube. Beam obstructed by one mask Remaining illuminance inside at the bottom of a standardised tube. General data Halogen bulb Order no. Life time of halogen bulb Automatic switch over to reserve bulb Dimensions Diameter of light body Diameter of Polygon Reflectors Light emission surface glass surface Max.

General data Halogen bulb at colour temperature K Order no. Halogen bulb at colour temperature K Order no. Part no. Measuring of the terminal voltage on the ceiling terminal. The terminal voltage of the emergency supply is similar to the reference value D. The reference value D. The secondary tap on the transformer should be chosen in that way that the above measured reference value D. This procedure is valid for separately mounted transformers with filtering board as well as on ceiling tube mounted transformers with filtering board.

The following taps can be chosen:. Example 1: Transformer and filtering board are mounted on the ceiling tube, emergency supply Example 2: Transformer and filtering board are mounted in the wall box, emergency supply The wires voltage drop is 2 V.

Attention: If the transformer and the filtering board are mounted separately, the wires voltage drop between the filtering boards output and the terminal connection of the ceiling tube has to be taken into account accordingly. If the transformer is mounted on the ceiling tube, the smallest secondary tap After the rectification on the filtering board, the above mentioned value corresponds to a D. How to proceed the transformer adjustment with topped filtering board : 1.

The wires voltage drop is 2. Due to the EMV conditions, the filtering board has generally to be connected and installed as near as possible to the transformer.

Please consider that the installed filtering board should be able to eliminate heat through a large surface. The wiring diagram please see page 72 - Reverse polarity protection, part no. If welded central columns are used, the module is installed on the flange.

A green LED on the reverse polarity protection module indicates the correct polarity, the presence of voltage as well as the functioning of the reverse polarity protection module. Light intensity power circuit board, part no. Dust extraction, waterspray and domiciliary options. Pack of 10 micro vacuum bags- suitable for all Berchtold Extraction Drills - - Made of microfilter material with plastic receptacle for the guide tube of the suction cover. LED flashlight for home visit case Elegant and solid foot care case for everyday use.

Black suitcase with nylon cover. Content mlfor the care and cleaning of handpieces with Intramatic couplingInstruCare is a highly pure instrument oil based on medical white oils for the care and protection of instruments. Visiting Case for podoQ and podoS - S50micro is not included in the price. For your water spray device Effective against microorganisms Micropur Classic inactivates bacteria in water tanks and containers. It keeps water free from germs, algae and odours.